PERFORMANCE DATA

ThermaCoustic Industries is committed to a policy of on-going product improvement and performance verification in and by various countries and jurisdictions.  The following table demonstrates compliance with standards required by Canada and the United States for the use of TC-417 GP in general building construction.

As our test program is on going, we continue to expand our list of qualifications (TC-417 GP is WH listed).  Therefore, if you are concerned about compliance with a particular standard not listed below, please contact us directly for current information.

Test Standard Test Requirement Result
Thermal Resistance ASTM C-518      Report Value RSI = 29.32/m [(m² • °C)/W]
R = 4.17/in. (hr • ft² • °F) / Btu
Thermal Conductance ASTM C-518 Report Value λ = 0.0346 W / (m² • °C)
K = 0.24 Btu • in / (hr • F² • °F)
Non-Combustibility CAN/ULC-S114
ASTM E-136
Non-Combustible Non-combustible
Surface Burning
Characteristics
ASTM E-84 &
CAN/ULC S102
Flame Spread ≤25
Smoke Developed ≤50     
Passed
Adhesion/Cohesion ASTM E-736 >1.7 kPa Passed
Noise Reduction Coefficient      ASTM C-423-99a
ISO 354
Report Value 50mm / 2" = 1.00
50mm / 2" = 0.95
Fungal Resistance MIL-STD 810E
Method 508.4
Report value No growth

[Previous] [Contents]


[Home] [Products] [Links] [Prospects] [Contact us] [Disclaimer]

ThermaCoustic Industries International Limited
Unit 108, 20119 - 113B Avenue, Maple Ridge, B.C., Canada, V2X 0Z1
Tel:  866.460.1474 or 604.460.1475 -- Fax:  604.460.1476 -- eMail:  info@thermacoustics.com

Copyright © ThermaCoustic Industries International Limited.  All rights reserved.
For more information, please review our disclaimer.