| Home | Products | Links | Prospects | Contact us |
TC-417-GP Thermal and Acoustic Solutions
Spray Applied InsulationGENERAL INFORMATION
(Applicable to both Thermal and Acoustic installations)FIRE SAFETY
TC-417 GP exhibits the following fire resistive attributes:
- Non-combustibility:
CAN/ULC S114 Non-combustible ASTM E-136 Non-combustible
- Surface burning characteristics:
To be approved for use in exposed locations, products such as TC-417 GP are required to exhibit the following surface burning characteristics:
Flame spread ≤ 25 Smoke developed ≤ 50 CAN/ULC S102 Flame spread: Passed Smoke developed: Passed ASTM E-84 Flame spread: Passed Smoke developed: Passed
- TC-417 GP is WH listed
For the peace of mind of all parties involved, we think it essential that any product used in a building interior that can be left exposed -- and is of more than film thickness - should contain very little, if any, combustible material.
Non-Combustibility versus Flame Spread:
There seems to be some confusion in the industry concerning the accepted definition of non-combustibility as compared to low flame spread. The distinction is quite simple:
- An organic substance such as paper can be treated with flame retardant material that ensures that it will burn slowly, and can then be considered to have a low flame spread;
- An organic material, even when treated with fire retardant and rated as 'low flame spread,' can never be rated as non-combustible because its flaming time, temperature rise and mass loss are more than allowed when subjected to industry-accepted test procedures;
- Only inorganic materials, or mixtures containing a very small organic component, can be rated non-combustible according to industry standards -- e.g. -- ASTM E-136, CAN/ULC S114.
The major component of TC-417 GP is inorganic glass fibre, and the product has been tested to CAN/ULC S114 and ASTM E-136 and rated as non-combustible. Since it is so rated, it can be applied to any fire resistive material without affecting the fire rating of the assembly.
Note: Unlike spray applied organic insulation materials, that can only qualify for low flame spread ratings, the low flame spread and non-combustible ratings of TC-417 GP are permanent. Therefore, it does not require either initial addition of a fire retardant at time of application or periodic top up of with fire retardant to maintain its ratings.
[Home]
[Products]
[Links]
[Prospects]
[Contact us]
[Disclaimer]
ThermaCoustic Industries International Limited
Copyright © ThermaCoustic Industries International Limited. All rights reserved.
Unit 108, 20119 - 113B Avenue, Maple Ridge, B.C., Canada, V2X 0Z1
Tel: 866.460.1474 or 604.460.1475 -- Fax: 604.460.1476 -- eMail: info@thermacoustics.com